SWR Drainage Pipes: Type A, Type B, Sizes and Slopes

SWR (soil, waste and rainwater) pipes are uPVC drainage pipes to IS 13592. Use Type B, the thicker wall, for soil and waste stacks and anything buried or exposed to knocks; Type A for rainwater downpipes and vents. Typical sizes are 110 mm for WC soil lines and 75 mm for basin, sink and floor-trap waste.

WhatsApp
Stack of plastic pipes
Plumbing & sanitary

How we supply it: SWR pipes and fittings are arranged through a partner plumbing dealer who quotes, supplies and bills them and pays us a referral commission. For the outside inspection chambers and drain beds, the 20 mm jalli, M-Sand and crusher dust come from us.

Also calledSWR pipe, drainage pipe, soil pipe, rainwater pipe, PVC drain pipe
StandardIS 13592 SWR pipes

In one line: SWR pipe is unplasticised PVC pipe for non-pressure drainage, used for soil (WC), waste (basins, sinks, floor traps) and rainwater lines and made to IS 13592.

What SWR stands for

SWR pipe is unplasticised PVC pipe for non-pressure drainage, used for soil (WC), waste (basins, sinks, floor traps) and rainwater lines and made to IS 13592.

Drainage runs by gravity, so slope and venting matter more than pressure rating. A well-vented, steadily falling line stays clear; a flat, unvented one smells and blocks.

Next question: What is the difference between Type A and Type B? More

Types, joints and fittings

SWR pipe types and common fittings
ItemWhat it isUse
Type ALighter wallRainwater downpipes, vent pipes
Type BThicker wallSoil and waste lines, buried runs
Ring-fit jointRubber ring in the socketLong vertical stacks; allows expansion
Solvent (self-fit) jointCemented socketShort branches and fittings
Floor (nahani) trap and multi-floor trapWater seal at floor drainsBathrooms, balconies, kitchens
Door bend and cleanoutOpening for roddingBends and stack bases

Next question: Which type for my lines? More

Type A or Type B?

Type B costs more per metre but takes knocks, sun and buried loads far better. The saving from Type A on a soil stack is small next to the cost of breaking a tiled wall to replace it.

Type B for every soil and waste line, buried run and exposed stack; Type A only for rainwater downpipes and vent pipes. Use ring-fit joints on long stacks that take full sun.

Next question: What size and slope? More

Sizes and slopes

These are typical house-site values; follow the plumbing drawing where one exists.

  • WC soil branch and soil stack: 110 mm
  • Basin, sink and floor-trap waste: 75 mm is common
  • Horizontal drains: a steady fall, commonly about 1 in 40 to 1 in 60 for 100–110 mm lines
  • Vent pipe carried above the roof with a cowl
  • Inspection chambers outside at every junction and change of direction

Next question: How do I check the work? More

Checks on pipes and joints

  1. The print should show IS 13592, Type A or B, size and batch.
  2. Look at a cut end: Type B's wall is visibly thicker than Type A's.
  3. Rubber rings should be seated in their grooves and slid in with the supplied lubricant.
  4. Plug the lower end, fill the stack with water and watch every joint.
  5. Check the fall of horizontal runs with a spirit level.

Next question: How should pipes and rings be kept? More

Storage

  • Keep rubber rings bagged and out of the sun.
  • Store pipes in shade, supported along their length, with sockets protected.
  • Do not stack bricks or bags on top of pipe bundles.

Next question: Which WC outlet goes on this line? More

Drainage mistakes

  • Type A on soil lines or buried runs.
  • No vent, so traps siphon dry and the bathroom smells.
  • Too little fall, so solids settle in the pipe.
  • Oil or grease used to slide rings in, which swells the rubber.
  • No cleanout at bends where blockages will happen.

Next question: Where does rainwater from the downpipes go? More

Questions buyers ask

SWR Drainage Pipes: questions buyers ask

What are the key differences between Class A and Class B pipes?

For SWR drainage pipes the terms are Type A and Type B under IS 13592. Type B has a thicker wall and is meant for soil and waste lines; Type A is lighter and meant for rainwater and vent pipes.

Which SWR pipe is best?

Type B for soil and waste lines, buried runs and anywhere pipes can be knocked; Type A only for rainwater downpipes and vents. Choose ring-fit joints on long vertical stacks so the pipe can expand in the sun.

What is the thickness of a Class B pipe?

It depends on the diameter. IS 13592 lists a minimum wall for each size, and Type B is always thicker than Type A of the same size. Check the type and size printed on the pipe and measure the wall at a cut end.

Which size SWR pipe for a toilet?

110 mm for the WC soil line and the soil stack; 75 mm is common for basins, kitchen sinks and floor traps. A larger pipe on the buried main drain to the septic tank or sewer never hurts.

Need SWR Drainage Pipes with your order?

Call, WhatsApp or send the quote form with it filled in: a partner supplier quotes, supplies and bills it, and we time it with your loads.